Sign In | Join Free | My burrillandco.com
Home > Vehicle Detector Sensor >

Adjustable Increments Vehicle Loop Detector 170kHz 10ms For Drop Barrier

SHENZHEN SINOMATIC TECHNOLOGY CO., LIMITED
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Adjustable Increments Vehicle Loop Detector 170kHz 10ms For Drop Barrier from wholesalers
     
    Buy cheap Adjustable Increments Vehicle Loop Detector 170kHz 10ms For Drop Barrier from wholesalers
    • Buy cheap Adjustable Increments Vehicle Loop Detector 170kHz 10ms For Drop Barrier from wholesalers
    • Buy cheap Adjustable Increments Vehicle Loop Detector 170kHz 10ms For Drop Barrier from wholesalers

    Adjustable Increments Vehicle Loop Detector 170kHz 10ms For Drop Barrier

    Ask Lasest Price
    Brand Name : SINOMATIC
    Model Number : PD-132
    Certification : CE/ ISO
    Price : negotiable
    Payment Terms : T/T, L/C, D/A, D/P, Western Union, MoneyGram
    Supply Ability : 3,0000pcs per month
    Delivery Time : 2-5 working days after payment received
    • Product Details
    • Company Profile

    Adjustable Increments Vehicle Loop Detector 170kHz 10ms For Drop Barrier

    Single Channel 110 V Drop Arm Barrier Gate Vehicle Loop Detector Parking Control System


    PRODUCT TECHNICIAL SPECIFICATIONS


    Supply voltage230VAC , 115V AC, 12V DC, 24V DC( See the label on the detector)
    Voltage tolerance AC+10% / -15%
    Voltage tolerance DC±15%
    Power Consumption4.5VA
    Output relays240V/5A
    Operating temperature-20°C to +65°C
    Storage temperature-40°C to +85°C
    Frequency range20kHz to 170kHz
    Reaction time10ms
    Signal holding timeUnlimited / limited when loop is permanently covered 10 minutes
    SensitivityAdjustable in 4 increments
    Loop inductanceTotal loop plus connection wiring:50μH to 1000μH.
    Ideal is 100μH to 300μH
    Loop connection wiringMaximum length 20 meters, twisted at least 20 times per meter
    Size of Housing78x40x108 mm (L x W x H)

    PRODUCT APPLICATIONS


    Automatic Gate
    Traffic Light System
    Gate Drive Mechanisms
    Operating Barriers
    Parking Guidance System
    Activating Card Dispensers in Parking Lots



    Main Features


    ♦ Industrial engineering design concept
    ♦ Standard industrial guide installation
    ♦ Strong anti-jamming ability and stability
    ♦ Variety of output interface adapted to different scene
    ♦ Variety of shape choice meet differentiation demand
    ♦ High temperature stability
    ♦ Environment drift automatic compensation function
    ♦ Coil automatic fault detection function

    ♦ When the DIP switch is on position or changing the presence output time, Self-detection would be done

    ♦ ABS align to the pillar which can combine with each other compactly
    ♦ Presence output time can be adjustable
    ♦ Work mode can be set by the DIP switch
    ♦ Pulse output or permanent output can be adjustable


    PRODUCT INSTALLATION


    The detector must be installed in a convenient weatherproof location as close to the loop as possible. Installation

    location must choose to stay away from the heat source, it around other devices must maintain a distance of at least

    10mm (mustn’t fix cling to the cabinet). A correct loop configuration and detector installation will ensure a successful

    inductive loop detection system. Loop of several important parameters include: loop figure, size, and turns, install

    methods (details as “Loop installation guide”).

    Work indicator


    Detector will enter into the self-calibration condition with the green LED flash, red LED extinguish once on power,

    this procession will last 1 second. .the vehicle should not on the loops within the self-calibration. The green LED will

    not flash, he red LED extinguish after self-calibration. When the vehicle past over the loop ,the red LED on.


    Operation and Indication


    While the detector is tuning, the green Channel LED and red Power LED will be turn on. It remain about 2 seconds,

    then the green LED turn off. If a loop fault exists the Channel LED will come on and flash indicating a fault. If the fault

    is self-healing the detector will continue to operate. The green channel LED will also glow whenever a vehicle is

    detected passing over the inductive loop. The red Power LED at the top of the unit will remain on to indicate that the

    unit is powered.


    Frequency


    To eliminate interference of two neighbouring wire loops or loop detectors, the frequency can be altered.

    Sensitivity


    The sensitivity of the detector allows the detector to be selective as to the change of inductance necessary to produce

    an output. There are four sensitivity selections and are set as follows by DIP3 and DIP4 Switch.